Topic: Thermal cut-out update | TB No.: TB10057 | Date: 10/06/2022 | |
Affected Machines: | All Ecoboiler/ Ecosmart range | Priority: Low | Created By: Eddie Purtil |
From Serial No.: | >03/20 | Created For: | Technicians |
From Date: | March 2020 | Pages: 1/1 |
UPDATE
A new Double pole overheat is being fitted to Eco boiler after serial no 0320XXXX.
*** The two versions of overheats will not be interchangeable. *** Must exchange like for like!
NOTE FOR ENGINEERS
The new overheat (1502075) will be fitted to the incoming live and neutral of the flex and when it trips it will cut the power to the boiler, not just the element like the older version (1502087) . This will mean than when it trips all the lights on display will go out and the error for not heating (4 flashes) will not be displayed.
PART CODES
Thermal Switch Dual Pole 125deg part no 1502075 Thermal Switch 130 deg part no 1502087.