Skip to main content
Topic:  Thermal cut-out update TB No.: TB10057 Date: 10/06/2022
Affected Machines: All Ecoboiler/ Ecosmart range Priority: Low Created By: Eddie Purtil
From Serial No.: >03/20 Created For: Technicians
From Date: March 2020 Pages: 1/1

UPDATE
A new Double pole overheat is being fitted to Eco boiler after serial no 0320XXXX.
*** The two versions of overheats will not be interchangeable. *** Must exchange like for like!

NOTE FOR ENGINEERS

The new overheat (1502075) will be fitted to the incoming live and neutral of the flex and when it trips it will cut the power to the boiler, not just the element like the older version (1502087) .  This will mean than when it trips all the lights on display will go out and the error for not heating (4 flashes) will not be displayed.

   

PART CODES

Thermal Switch Dual Pole 125deg  part no 1502075                  Thermal Switch 130 deg  part no 1502087.