Skip to main content

Muller Pump Service Instruction

Note: To replace two pumps in SP9 or Jet Twin two kits are required

1501562K – Muller Pump Spares kit A (MIX, Jet & SP9)

1501562 Pump Muller 24V Mini 1
1501563 Flow Reducer 9mm OD 4mm ID 1
1500582 Splice Connector Insulated 26 – 19 AWG 2
8800456 Double Sided Adhesive Square, 25mm x 25.4mm 1

Procedure
1. Turn off the machine.
2. Disconnect the electrical supply from the mains.
3. Drain the machine fully.
4. Remove service panels.
5. Disconnect electrical supply to pump.
6. Remove old pump.

NOTE step 7 is for SP9, Jet and Jet Twin only.

7. Insert flow reducer (1501563) into pump outlet tubing. Wet the reducer beforehand to lubricate and if required use the blunt end of a biro to push the reducer in far enough to leave room for the pump connection.


NOTE: Step 8 is for Jet Twin Only.
8. Wire new pumps together (red to red & black to black) using splice connector 1500582.

 


9. Place double sided adhesive square on the base of the pump to adhere to the chassis.
10. Insert pumps into tank location.
11. Rewire and re-plumb pumps.
12. Reassemble service panels.
13. Plug machine back into mains and turn on.
14. Wait for the machine to fully recover.
15. Recalibrate machine.